spcat-considerations

This is an old revision of the document!


Some considerations for using SPCAT

The two files required for running SPCAT to carry out a forward calculation of a spectrum are the intensity file and the variance file with the names file.int and file.var, respectively. The variance file is created by SPFIT from the parameter and line files. In the case of an initial forward calculation without any fit, you can use a parameter file instead, but turn the large variability of the parameters into small or very small ones to obtain some very crude estimation of the uncertainties.

You will find information on how to set up a parameter or variance file in Herb Pickett's documentation or the the essentially equivalent section General. Additional information may be gained through the numerous examples. There is not much to pay attention to in the variance file, except the value of <i>K</i>max. In the case of SPCAT, its value is important for the calculation of the partition function values as you will see below.

The intensity file consists usually of three or more lines.
* The first line is the title line. This will be written into the output file (file.out). It could be the name or the formula of your molecule with additional information if desired.
* The second line contains a number of options to describe the forward calculation, see also Herb Pickett's documentation or the the essentially equivalent section General. Further details are given below.
* The third and subsequent lines contain information on the dipole moment components etc. If you want to calculate only an energy file, partition function values etc., you may add a blank line between the second and the third line. This causes the dipole moment informations to be ignored.

The option line contains the following quantities:
FLAGS, TAG, QROT, FBGN, FEND, STR0, STR1, FQLIM, TEMP

* FLAGS: the most important ones are 0 for a short output file without energy file and 1 for the calculation of an energy file in addition. If all of your frequencies and parameter values are in units of inverse centimeters, add 1000 to FLAGS for proper calculation of the partition function. If you use püarameter values in megahertz units, you can use units of inverse centimeters for a transition frequency or energy value by putting a minus sign in front of the uncertainty.

* TAG: The tag is used in a catalog file to identify a species. Up to six characters may be used. The first up to three digits in the CDMS reprsent the molecular weight of the molecule in atomic mass units, next come a 5, and two digits for counting.

* QROT is the value of the partition function at the desired temperature. The default temperature is 300 K. Considerations for Evaluating the partition function are given separately below.

* FBGN is the F (or J or N) value at which the calculation should start.
* FEND is the F (or J or N) value at which the calculation should end.
Please note: While your calculation usually should start at 0, you may want to run only a partial forward calculation if you are interested in a subset of transitions. You want to end your calculation at values at which the uncertainties of transition frequencies are not excessively large. But read also the considerations for Evaluating the partition function below.

* STR0 is the first cutoff value of the decadic logarithm of the intensity in the intensity units employed in the catalog file. It is applied linearly!
* STR1 is the second cutoff value of the decadic logarithm of the intensity in the intensity units employed in the catalog file. Basically, the intensity Int has to fulfil the following:

Int > 10STR0 + (v/300)2∗10STR1, where v is the transition frequency in units of gigahertz.

Additional information is given in the section Considerations for the intensity cutoffs.

* FQLIM is the upper frequency limit in units of gigahertz.

* TEMP is the temperature. The default value is 300 K. Any other temperature may be chosen as long as the partition function value may be evaluated at this temperature.

It is quite obvious that at least fairly accurate dipole moment components are required for the calculation of reliable intensities. Such data are occasionally available from experiments and sometimes from quantum-chemical calculations. It is certainly useful to try to determine experimental values wherever this is possible. Quantum-chemical calculations should always be viewed with a grain of salt as calculations may be tough in some cases. Moreover, in some cases, the molecules are not in the principal axis system or some axes have been interchanged.

SPCAT calculates the partition function by default at the temperatures of 300, 225, 150, 75, 37.5, 18.75, and 9.275 K by direct summation of the contributions of quantum levels as specified in the intensity and variance files. Other temperatures will be calculated individually as specified by TEMP in the intensity file. Therefore, it is of utmost importance to take a number of aspects into account.